cc/td/doc/product/core/cis7000
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Numerics
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
R
S
T
U
V
W
X

Numerics


100BASE-FX     73

100BASE-T     73

100BASE-TX     73

10BaseT     91

16 Mbps LED on TRIP
See LEDs

16-bit CRC
See CRC     207

4 Mbps LED on TRIP
See LEDs

A


AC Power LED on power supply
See LEDs

AC power, input     25

acronyms, definition of     17

active monitor in Token Ring network     96

addresses, ports     54

agency approvals     21

AIP
cable connections     125
LEDs     268
microcode ROM replacement     166

air
cooling     21
dam     21
exhaust     63
filter
and environmental monitor     63
cleaning     237
flow     20, 26

AMD SuperNet chipset     44

ANSI X3.1     45

ANSI X3.1 standard     99

arbiter
replacing     246

arbiter board     246

arbiter, description of     21, 23

arbitration, CxBus     21

Asynchronous Tranfer Mode (ATM) Interface Processor
See AIP

attachment unit interface
See AUI

AUI
connector pinouts     250
EIP ports     42

autoreconfiguration in Token Ring network     96

auxiliary port     107
pinouts     250

auxiliary port, description     31

B


backplane
description     21
interface processor connections     158
slot keys     23
speed     20

back-up batteries     30

batteries, lithium backup     30

baud-rate settings     178

beaconing on ring network     96

blower
air flow path (illustration)     21
and environmental monitor     62
description     26
noise     152
replacing     242

boot command     170

Boot Error LED on RP
See LEDs

boot filenames     171

boot system flash command     148

boot-load failure     172

bootload-failure response     178

Break key (interrupt)     177

broadcast address destination, configuration register settings     178

broadcast address, setting     172

burn in     151

bus
arbitration     21
CxBus     17
traffic control     23

bypass switch, optical for FDDI     98

C


CAB-ATM-DS3/E3     126

cable
MIP     102

cables
100BASE-T     73
AC power     25
attaching
FEIP     129
avoiding crossing     124
connecting external     124
console     84
console port     250
distance limitations     72
E1-G.703/G.704     104
Ethernet transceiver     250
Fast Ethernet specifications     73
FEIP     93
guidelines     124
hazardous     70
interference     72
lobe (Token Ring)     94
MII and RJ-45, FEIP     93
MII specifications     73
optical bypass     253
patch (Token Ring)     94
power     229
retention clip, power     229
strain relief     166
swapping power     154
Token Ring     252
ungrounded     70
uninsulated     70

captive installation screws
for ESD prevention     70
interface processors     156, 163
power supply     24, 232

caution
description     xv
EMI filter clip     86, 88
hanging the router     174
reset switch     267

Channel Interface Processir
See CIP

chassis
clearance     63
dimensions     20
front panel     18
internal components     21, 238
lifting     68
panels, removing     233
physical specifications     20
rear view (illustration)     19
top-down view (illustration)     22
warning against stacking     21

checklist, installation     112

CIP
LEDs     269
microcode ROM replacement     166

Cisco Extended Bus
See CxBus

cleaning the air filter     237

clearance, chassis     63

clock
acceptable rates     206
arbiter     23

clockrate command     206

Collision LED on EIP
See LEDs

commands
b (boot)     176
boot     170
boot system     177, 181
boot system flash     178
boot system flash filename     148, 178
Break (interrupt)     177
clockrate     206
config-register     148, 175, 177, 178, 181
configure     164
configure terminal     175, 177, 181
copy     146
crc32     208
early token release     97
enable     175, 181
Flash-related     176
i (initialize)     180
invert-transmit-clock     206
microcode card rom     167
microcode reload     168
nrzi encoding     207, 208
o/r (reset)     180
reload     176
ring-speed     97
setup     164
show configuration     180
show controller     164, 167
show controller cxbus     209
show environment     63, 83
show interfaces     56, 164
show version     176, 180

concentrator     101

config-register command     148

configuration
register
boot field     176

configuration notes, description of     157

configuration register, description     169

configuration worksheet     111, 124

configure command     164

Conn LED on FSIP
See LEDs

Conn LED on SIP
See LEDs

connector     251
auxiliary port     250
console port     250
DB-9     44
DIN     98
Ethernet     250
FC     45
MIC     45
MII and RJ-45     93
mini-DIN     46, 253
optical bypass switch     253
RS-232     50, 254
RS-449     50, 255
Token Ring     252
TRIP     252
V.35     50, 257
X.21     50

console
cable     84
terminal     153

console port     107, 250
baud rate     172
description     31
pinouts     250
settings     178

conventions
See document conventions

cooling subsystem     152

copy command     146

copying to Flash     179

CPU
FSIP     46
system     153

CPU Halt LED on RP
See LEDs

CRC
configuring     207
description of     105

crc32 command     208

Critical status level, environmental monitor     62

CSU     85

current rating, chassis     20

CxBus     17
arbitration     21

Cyclic Redundancy Check
see CRC

D


damage from overheating     61

danger, warning
description     xv

DAS
description     99

DB-9 connector     44

DC Fail LED on power supply
See LEDs

DC power     62
and environmental monitor     62
voltages     151

DCE
clock signals     206
devices     137

debug commands     172

dimensions
chassis     20
interface processors     38

DIN connector     253

displays, environmental     63

document conventions     xv

downloadable microcode     165

downloadable microcode, description of     58

DRAM     28

DSU     85, 137

DTE
devices     137

dual attachment stations
See DAS

dual homing
description     101

dual ring
description     99

dual-attached station     45, 273

dust     237

E


E1-G.703/G.704
cables     104

early token release     96

early token release command     97

EIA 310C     21

EIP
description of     41
LEDs     271
microcode ROM replacement     166
port signals     250
speed     38

ejector levers     156
description     20

electromagnetic pulse (EMP), avoiding     72

electrostatic discharge     71

EMI filter clip, AIP     126

enable command     181

Enabled LED on interface processors     39

enabled LED on interface processors     152
See LEDs

environmental monitor description     61

EPROM     28

error correction, CRC     106

ESD prevention     71

Ethernet     73
AUI connector pinouts     250
AUI port signals     250
cables     250
connector locks     92
ports on EIP     42
transceiver     42, 85, 91, 163

Ethernet interface processor
See EIP

example of port addresses     55

examples
copying
images to a Flash memory card     146
ring-speed command     130

exhaust air     63

F


faceplates     156

factory burn in     151

failure
AC source     62, 264
boot-load     172
power supply, DC section     264

Fast Ethernet Interface Processor
See FEIP

fast serial interface processor
See FSIP

fault management
Token Ring     96

FC connector     45

FCS, and CRC     207

FDDI
FIP description     44
interface processor
See FIP
optical bypass switch     253

FEIP
cable attachment     129
cables and connectors     93
LEDs     272
microcode EPROM location     166
pinouts     251
product numbers and descriptions     43
See also Fast Ethernet

field-replaceable unit
See FRU

filenames, netbooting     177

filler, interface processor     163

filter, air     63

filter, avoiding wet     237

FIP
description of     44
LEDs     272
microcode ROM replacement     166
mini-DIN signals     253
speed     38

Flash
copying to     179
downloading images into     30
loading microcode from     168
write protect jumper     168
write-protection     173

Flash memory
copying files     146

frame check sequence     207

frequency, specifications     20

front panel
description of     18
LEDs     18

FRU
definition of     17

FRUs     246

FSIP
description of     46
interface pinouts     253
LEDs     275
modes, description     47
speed     38

G


gravity, maintaining low center     20, 81

guides, backplane slot keys     22

H


Halt LED on RP     31

handles
interface processors     70, 163

heat dissipation     20

High-Level Data Link Control (HDLC)     85

high-speed serial interface processor
See HIP

HIP
LEDs     277
microcode ROM replacement     166
speed     38

HSSI
cable pinouts     260
LEDs     277

HSSI interface processor
See HIP

humidity, specifications     21

I


i command (initialize and reboot)     180

IBM
and NRZI format     105
Token Ring network, description     94

IBM, chipset on TRIP     43

IEEE
802.3u     73

IEEE 802.3
and EIP     41

IEEE 802.5
and TRIP     94
specification     94

images, downloading     30, 164

In Ring LED on TRIP
See LEDs

injury
avoiding     68

inlet air     66

installation checklist     112

interface
configuration     151

interface processors
carriers     162
configuration     158
description of     38
dimensions     38
enabled LED     268
installation     158
LEDs     39
slot keys     23
troubleshooting     155

interface types supported     19

interlock, power supply     24, 119, 230

intermittent powerfails     63, 64

inverted clock     206

invert-transmit-clock command     206

ISO 9314     45

J


jackscrews
FEIP MII connector     93

jewelry, avoiding for safety     68

K


key, Break (interrupt)     177

keys, backplane slots     23

L


label, chassis serial number     151

laser radiation     124

last, show environment     64

LED board
replacing     238

LEDs
AIP     268
Boot Error     266
CIP     269
CPU Halt     266
DC Fail      264
EIP      41, 271
Enabled on interface processors     39
FEIP     272
FIP     45, 272
FSIP     48, 275
HIP     277
interface processor     39
interface processor enabled     268
MII, link, and RJ-45     272
MIP     278
Normal on power supply     263
PCMCIA slots 1 and 2     267
power supply     24, 153, 264
RP     31, 153, 266
serial ports     275
system     18, 263
TRIP     44, 279
Upper Power     18

levels, status for environmental monitor     62

lifting the chassis     68

lightening storm, safety during     70

Link LED     272

load sharing, power     20

lobe cables, Token Ring     94

locked blocks
recovering     149

log, environmental     63

Lower Power LED on power supply
See LEDs

M


MAU     85
EIP interface to     42
TRIP interface to     44, 252

maximum configurations     54

maximum distance limittaions     73

memory
system     28

memory, Flash
See Flash

messages, environmental     63

MIC connector     45

microcode
and troubleshooting     153
ROM replacement     166
specifying file to load     167

microcode card rom command     167

microcode reload command     168

microcode, downloadable     38, 58

MII
cable attachment     129
cable specifications     73
connections, FEIP     93
LED     272
pinouts     251

mini-DIN connector     46, 98

MIP
cables     102
LEDs     278
microcode ROM replacement     166
speed     38

modem     85

MSAU, description     94

MultiChannel Interface Processor
See MIP

multimode FIP
description     44

multistation access unit
See MSAU

N


neighbors,upstream and downstream     100

netbooting     176

noise
blower     152

Normal LED
See LEDs

Normal LED on RP
See LEDs

Normal status level, environmental monitor     62, 64

note
description     xv

NRZI encoding     205

NRZI Format
description     105

NRZI format
configuring     207

nrzi-encoding command     207, 208

null modem cable
pinouts     260

numbers, port     55

NVRAM     28
description of     30
log     62

O


o/r command (reset)     180

OIR
functional description     57
interface processor support     38
onscreen messages during     164
overview     158
screen displays during     164

online insertion and removal
See OIR

operating conditions
for chassis     21

operating temperature     20

optical bypass cable     46

optical bypass switch
cable pinouts     253
functional description     101

out-of-tolerance condition     62, 264

overheating
preventing     21

overtemperature conditions     151

P


password, recovering     180

patch cables, Token Ring     94

PCMCIA
formatting a new card     145

PHY A/B LEDs on FIP
See LEDs

PHY, description     99

physical port addresses     55

physical sublayer
See PHY

pinouts
FEIP     251

port
addresses     54
auxiliary     31, 107
console     31, 107
densities     54
EIP     250
Ethernet     250
RS-232     50, 254
RS-449     50, 255
Token Ring     251
V.35     50, 257
X.21     50

port adapter cables
pinouts     253

port adapters
description of     49, 98
installation     210

power
+24V DC line     62
cord     25, 68, 154
DC status     62
disabled     62
emergency switch     70
loss     264
normal startup sequence     153
ramp down     62
redundant, description of     20, 61
safety     69
service     125
site     71
specifications     20
subsystem, for troubleshooting     152
surge suppression     72
troubleshooting     154
ungrounded     70

power factor corrector     20, 71

power supply
active     264
and environmental monitor     62
bay     18, 19, 119, 154
description     24
description of     20
installation     229
LEDs      24, 153, 264
removing     230
safety interlock     69, 119, 230
shutdown     62, 264
specifications     20
troubleshooting     152

powerfails     64

procedures
copying to Flash     179
maintenance     ?? to 180
recovering from a lost password     180

processor
shutdown     62

processor modules, definition of     20

protocols     17

R


radio frequency interference (RFI)     72

Receive LED on EIP
See LEDs

recovering a lost password     180

redundant power
description of     20

redundant power, description of     61

refresh, environmental display     64

reliability, system     17

reload command     176

replaceable system components     157

reports, environmental     63

reset switch     267

ring
in Token Ring networks     94

ring recovery
description     100

rings, primary and secondary     46

ring-speed command     97

RJ-45
cable attachment     129
cable specifications     73
connections, FEIP     93
LED     272
pinouts, FEIP     251

ROM
booting from     169
microcode     166

ROM monitor, system boot     171

route processor
See RP

RP
configuration     158
configuring     168
description of     26
Flash write-protection     173
installation     158
LEDs     153, 266
normal startup     153
replacing     168
slot key     23

RS-232
cable pinouts     254
description     107
port     254
port adapter     50
serial port adapter cable     103

RS-449
cable pinouts     255
description     107
port adapter     50
serial port adapter cable     103

RS-530
cable pinouts     258
description     108
serial port adapter cable     103

RxC LED on FSIP
See LEDs

RxD LED on FSIP
See LEDs

S


safety recommendations     68

SAS
description     99

self-check messages     172

sensors, temperature     64

serial
port adapters     49
ports, LED indications     275

serial interface processor
See FSIP

serial port adapters
description     49

setup command facility     164

show controller command     164, 167

show controller cxbus command     209

show environment command     63, 83

show interface command     56

show interfaces command     56, 164

shutdown
environmental     61
power supply     62, 264
processor     62

signal loss with optical bypass     46

Silicon Switch Processor
See SSP

single attachment stations
See SAS

single-mode FIP
description     44

SIP
microcode ROM replacement     166

site, cabling     72

slot
locations     19
numbers     55

SMDS networks and CRCs     207

software
upgrades     158

software commands     17

SP
configuration     158
description of     36
installation     158
microcode ROM replacement     166
normal startup     153
slot key     23
troubleshooting     155

specifications
chassis, physical     20
Fast Ethernet     73

SRAM, FSIP     46

SSP
configuration     158
installation     158
microcode ROM replacement     166

standards, ISO 9314     45

startup     152

statistics, environmental     65

status
environmental     64
power supply     25
system LEDs     18

subsystems for troubleshooting     152

switch
reset     267

switch processor
See SP

switch, optical bypass     46, 98, 253

system
architecture (illustration)     22
banner     153
boot instructions     169
components, descriptions of     21, 111
functional overview     54
internal components     238
LEDs     18, 263
lifting     68
maximum configurations     54
problems at startup     151
replaceable components     157
upgrades     157

T


T1 network connections     85

telephone jacks     70

temperature
internal chassis     61
parameters for environmental monitor     66
power supply     265
sensors     64
specifications     21

thresholds
environmental     62
shutdown     61

time saver
description     xv

Token Ring
autoreconfiguration     96
beaconing     96
cable pinouts     252
cables     252
MAU     93
ports     251

Token Ring interface processor
See TRIP

traffic on CxBus     23

transceiver
Ethernet     42, 91, 250
fiber optic     46

Transmit LED on EIP
See LEDs

TRIP
LEDs     279
microcode ROM replacement     166
port signals     251
speed     38

TxC LED on FSIP
See LEDs

U


Universal (cable unattached) message     209

upgrades
microcode     164

upgrades, system     157

Upper Power LED on power supply
See LEDs

V


V.35
cable pinouts     257
description     108
port adapter     50
serial port adapter cable     103

vacuuming, air filter     237

virtual configuration register
functions     174  to 179

voltage
input     20
out-of-tolerance condition     62

W


warning
against stacking the chassis     21
description     xv
environmental     66

weight, chassis     20

wiring
color codes     281
second scheme     283
interference     72
plant     72
telephone     70
telepnone industry 25-pair color code     281

write-protect, Flash     168

X


X.21
cable pinouts     256
description     108
port adapter     50
serial port adapter cable     103


hometocprevnextglossaryfeedbacksearchhelp
Posted: Thu Nov 1 15:58:12 PST 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.